General and large mobile lighting products

type question

Solution

illumination Lamp

Check whether the input voltage is normal. If the line connection is not normally check, please contact the local service center for maintenance as if it is normal.

The cylinder cannot rise normally Check whether the air pump switch is turned on, check whether the bronch is connected, and whether the air is leaked.If normal, please contact the local service center for repair.
The cylinder cannot be completely reset Remove the cylinder load (lamp dish). After the air pump is inflated with the cylinder, the cylinder shakes, and then press the exhaust valve to reset the cylinder.If you cannot solve it, please contact the local service center for repair.
Diesel Generator FAQ Unable to start

1. Preliminarily determine whether diesel, engine oil, cooling water and other fuels are sufficient, and add them based on the judgment; 2. Preliminarily determine whether the engine group circuit is normal, and replace and eliminate the components of the relevant control circuit based on the judgment; 3. Preliminarily determine whether the starting battery is normal, and charge or replace the battery based on the judgment.

Oil leakage Check whether there is a failure of the relevant oil unloading valve and perform component repair or replacement according to the judgment.
Frequent flames after starting Initially judge whether the air filtering, diesel filtering, oil filtering, oil and water separator, etc. on the mobilization unit are normal, whether it is necessary to clean, if there is a problem, please contact the service center to maintain and maintain it.
Abnormal situation In addition to the above five cases, the fault code and other abnormal conditions on the intelligent control panel are contacted. Please contact the local service center for repair.
Gasoline Generator FAQ Spark plug jumping fire Clean the surface area of the surface area with a wire, and then clean the internal carbon with steel needles.If you still cannot solve it, replace the spark plug.
No voltage output 1. Use a multimeter to measure whether there is voltage on the socket. If the voltage is normal, replace the voltmeter. 2. Confirm whether the circuit breaker is turned on. 3. If the above is normal, confirm the fault by swapping the AVR. 4. If the AVR is normal, confirm whether the generator stator or rotor is burned. If so, replace it. If the above inspection still cannot solve the problem, please contact the local service center.
Can't start the pull disk or start the blue smoke Replace the oil and re -clean or replace the spark plug.If you still cannot solve it through the above investigation, please contact the local service center.
Mixed oil mixed with gasoline First clean the floating sub -valve of the carburetor. If it cannot be solved, replace the carburetor; and replace the oil in the cylinder.If you still cannot solve it through the above investigation, please contact the local service center.
Start the pine Disassemble the original startup plate and replace the new pull -up components.
Other problems abnormalities Except for the above problems, please contact the service center in time to maintain maintenance and maintenance in time